Renovation permit
333 SEYMOUR STREET
Vancouver , British Columbia
- Issued
- Issued Aug 10, 2018
- Project type
- Renovation
- Value
- $700K
- Status
- Issued
Activity at this address
39 permits since 2017
Most recent activity: Jul 2026
Renovation
This permit is one of 39 permits filed at this address.
Permit details
The municipal record for this permit.
- Issue date
- Aug 10, 2018
- Project value
- $700K
- Project type
- Renovation
- Building type
- Commercial
- Commercial category
- Office
- Description
- Field Review - Addition / Alteration - #500-5th floor (full floor tenant) Interior alterations for interior demolition and tenant improvements for a new full floor office tenant which will occupy all 4 suites on the 5th floor of this existing commercial building. Maximum occupant load is 200 as per letter dated August 27, 2018. *UPDATE: REVISION #1: See letter from MKThink dated December 10, 2018. Scope of work: interior demolition of all partitions and demising walls and construct new demising walls and new partitions for new layout of the 5th floor. Work includes new convenience washroom, updates to common washrooms, new millwork and finishes, card reader, electrical, plumbing, mechanical and sprinkler work. REVISION #1: - revise occupant load: Maximum occupant load is 200 as per letter dated August 27, 2018. - add to TENANT: WeWork "tenant occupies floors 4-10" Sept.6/18 jm Address Note: Suite numbers to be posted by suite entry prior to final building inspection. REVISION #2 - See new complete set of revised plans (now 33 pages) to show reduction in value of work from $1,000,000 to $750,000, new RCP (ASHRAE), all to reflect layout change/redesign. Demising walls removed and #500 is assigned to this full floor suite now. Refer to Operational Letter dated December 10, 2018 from MKThink (regarding occupancy calculations) and authorization letter dated December 7, 2018 from original applicant L. Schmidt. January 15, 2019 jm TENANT: WeWork (tenant occupies floors 4-10) Letters of Assurance submitted by: - Schedule A and Architectural Schedule B, Steven A. Kelley, AIBC, 415.288.3380 - Mechanical/Plumbing Schedule B, Flavio Bertolo, P.Eng, 647.260.3440 - Electrical Schedule B, Jay Oleson, P.Eng, 206.493.2243 OK for FLD RVW per I. Batt July 18/2018 No energy upgrade required. BOMA BESt building. Note: No locks present on elevator lobby doors.
- Contractor
- Canadian Turner Construction Company Ltd
- Permit status
- Issued
- Applicant
- Laurie Schmidt DBA: Schmidt & Associates Development Planning Ltd
References & corrections IDs · source · attribution
Permit ID
BP-2018-03894
Full address
333 Seymour St, Vancouver, BC, Vancouver, V6B
Page URL
Contains information licensed under the Open Government Licence, City of Vancouver.