New Build permit
533 COLLEGE ST
Toronto , Ontario
- Issued
- Issued Oct 11, 2019
- Project type
- New Build
- Status
- Completed
Activity at this address
20 permits since 2003
Most recent activity: Aug 2023
This permit is one of 20 permits filed at this address.
Revision history
5 revisions on file · 2019–2021
-
Closed Rev 04 Issued Dec 23, 2021
Revision 4 - Fire/ Security upgrade in existing mixed-use buildin, supply and install novec systemRevision 3 - Remove from scope of work office retrofit on the second floor and keep the existing tenan… Read full revision note Show less
Revision 4 - Fire/ Security upgrade in existing mixed-use buildin, supply and install novec systemRevision 3 - Remove from scope of work office retrofit on the second floor and keep the existing tenant facility (fitness centre) as is. Some areas of the second floor are excluded from this revision, basebuilding upgrade (stair A and B elevator, mechanical shafs, electrical room) all other spaces remain as is.REV - 02 The revision simplifies exit stair layout. The exit stair B is not rotated at level 4 and terrace, it follows typical floor stair plan. Minor mechanical changes and design updates.Proposal for underpinning, interior alterations, and roof reinforcement in existing multiple unit building with retail and office use. Scope of work includes new sprinklers and fire alarm system.
-
Closed Rev 03 Issued Feb 05, 2021
Revision 3 - Remove from scope of work office retrofit on the second floor and keep the existing tenant facility (fitness centre) as is. Some areas of the second floor are excluded from this revision,… Read full revision note Show less
Revision 3 - Remove from scope of work office retrofit on the second floor and keep the existing tenant facility (fitness centre) as is. Some areas of the second floor are excluded from this revision, basebuilding upgrade (stair A and B elevator, mechanical shafs, electrical room) all other spaces remain as is.REV - 02 The revision simplifies exit stair layout. The exit stair B is not rotated at level 4 and terrace, it follows typical floor stair plan. Minor mechanical changes and design updates.Proposal for underpinning, interior alterations, and roof reinforcement in existing multiple unit building with retail and office use. Scope of work includes new sprinklers and fire alarm system.
-
Closed Rev 02 Issued Aug 26, 2020
REV - 02 The revision simplifies exit stair layout. The exit stair B is not rotated at level 4 and terrace, it follows typical floor stair plan. Minor mechanical changes and design updates.Proposal fo… Read full revision note Show less
REV - 02 The revision simplifies exit stair layout. The exit stair B is not rotated at level 4 and terrace, it follows typical floor stair plan. Minor mechanical changes and design updates.Proposal for underpinning, interior alterations, and roof reinforcement in existing multiple unit building with retail and office use. Scope of work includes new sprinklers and fire alarm system.
-
Closed Rev 01 Issued Oct 11, 2019
REV - 01 for changes approved by Committee of Adjustment.Proposal for underpinning, interior alterations, and roof reinforcement in existing multiple unit building with retail and office use. Scope of… Read full revision note Show less
REV - 01 for changes approved by Committee of Adjustment.Proposal for underpinning, interior alterations, and roof reinforcement in existing multiple unit building with retail and office use. Scope of work includes new sprinklers and fire alarm system.
-
Closed Rev 00 Issued Feb 04, 2019
Proposal for underpinning, interior alterations, and roof reinforcement in existing multiple unit building with retail and office use. Scope of work includes new sprinklers and fire alarm system.
Every revision the municipality has published for this permit, read directly off the source record rather than the single collapsed status most permit trackers show.
Permit details
The municipal record for this permit.
- Issue date
- Oct 11, 2019
- Project value
- —
- Project type
- New Build
- Building type
- Multi Family
- Description
- REV - 01 for changes approved by Committee of Adjustment.Proposal for underpinning, interior alterations, and roof reinforcement in existing multiple unit building with retail and office use. Scope of work includes new sprinklers and fire alarm system.
- Builder name
- —
- Permit status
- Completed City's exact wording: Closed
- Work type
- Building Additions/Alterations
- Completed
- 2022-01-24
References & corrections IDs · source · attribution
Contains information licensed under the Open Government Licence, City of Toronto.
CanPermits is not perfect.
Please correct us.
Nearby active addresses