New Build permit
357 BAY ST
Toronto , Ontario
- Issued
- Issued Nov 03, 2020
- Project type
- New Build
- Value
- $4.7M
- Status
- Completed
Activity at this address
19 permits since 1997
Most recent activity: Nov 2020
This permit is one of 19 permits filed at this address.
Revision history
3 revisions on file · 2020–2022
-
Closed Rev 02 Issued Sep 14, 2022
REV 02 - CONSTRUCTION OF NEW PARTITIONS & FINISHES, INSTALLATION OF A NEW GF UNIVERSAL WASHROOM, & CREATION OF NEW INTERNAL OPENING AT GF LOBBY, REFER TO ALTERNATE SOLUTION. NO CHANGES TO THE EXIST. B… Read full revision note Show less
REV 02 - CONSTRUCTION OF NEW PARTITIONS & FINISHES, INSTALLATION OF A NEW GF UNIVERSAL WASHROOM, & CREATION OF NEW INTERNAL OPENING AT GF LOBBY, REFER TO ALTERNATE SOLUTION. NO CHANGES TO THE EXIST. BASE BUIDLING MECH. OR ELECT. SERVICES OR STRUCTURAL SYSTEMS ARE PROPOSED. EXIST STAIRS & FIRE RATED ASSEMBLIES WILL REMAIN IN THEIR EXIST. CONFIGURATION.REV 01: REDUCE FIRE SHUTTER SIZE AT MEZZANINE LEVEL AS PER OPTION 1 OF APPLICATION #20 171409 ALT 00 AS. PROPOSAL FOR INTERIOR RENOVATIONS (TENANT FIT-OUT) TO FLOORS 1 (GROUND), 2 AND 2M (MEZZANINE). SCOPE OF WORK INCLUDES CONSTRUCTION OF NEW PARTITIONS AND FINISHES, INSTALLATION OF MECHANICAL AND ELECTRICAL DISTRIBUTION, INSTALLATION OF NEW WASHROOMS INCLUDING PLUMBING AND FIXTURES, NEW LIGHTING, REINSTATEMENT OF OPENING IN 2M FLOOR WITH ASSOCIATED STRUCTURAL WORK, 2HR FRR BETWEEN 2 AND 2M FLOORS MAINTAINED WITH 2HR FRR GWB PARTITIONS AND FIRE SHUTTERS. CHANGE OF USE AT GROUND FLOOR FROM RETAIL (GROUP E) TO OFFICES (GROUP D). Base building work done under #18 256994 BA
-
Closed Rev 01 Issued Mar 03, 2021
REVISION#1: REDUCE FIRE SHUTTER SIZE AT MEZZANINE LEVEL AS PER OPTION 1 OF APPLICATION #20 171409 ALT 00 AS. PROPOSAL FOR INTERIOR RENOVATIONS (TENANT FIT-OUT) TO FLOORS 1 (GROUND), 2 AND 2M (MEZZANIN… Read full revision note Show less
REVISION#1: REDUCE FIRE SHUTTER SIZE AT MEZZANINE LEVEL AS PER OPTION 1 OF APPLICATION #20 171409 ALT 00 AS. PROPOSAL FOR INTERIOR RENOVATIONS (TENANT FIT-OUT) TO FLOORS 1 (GROUND), 2 AND 2M (MEZZANINE). SCOPE OF WORK INCLUDES CONSTRUCTION OF NEW PARTITIONS AND FINISHES, INSTALLATION OF MECHANICAL AND ELECTRICAL DISTRIBUTION, INSTALLATION OF NEW WASHROOMS INCLUDING PLUMBING AND FIXTURES, NEW LIGHTING, REINSTATEMENT OF OPENING IN 2M FLOOR WITH ASSOCIATED STRUCTURAL WORK, 2HR FRR BETWEEN 2 AND 2M FLOORS MAINTAINED WITH 2HR FRR GWB PARTITIONS AND FIRE SHUTTERS. CHANGE OF USE AT GROUND FLOOR FROM RETAIL (GROUP E) TO OFFICES (GROUP D). Base building work done under #18 256994 BA
-
Closed Rev 00 Issued Nov 03, 2020
PROPOSAL FOR INTERIOR RENOVATIONS (TENANT FIT-OUT) TO FLOORS 1 (GROUND), 2 AND 2M (MEZZANINE). SCOPE OF WORK INCLUDES CONSTRUCTION OF NEW PARTITIONS AND FINISHES, INSTALLATION OF MECHANICAL AND ELECTR… Read full revision note Show less
PROPOSAL FOR INTERIOR RENOVATIONS (TENANT FIT-OUT) TO FLOORS 1 (GROUND), 2 AND 2M (MEZZANINE). SCOPE OF WORK INCLUDES CONSTRUCTION OF NEW PARTITIONS AND FINISHES, INSTALLATION OF MECHANICAL AND ELECTRICAL DISTRIBUTION, INSTALLATION OF NEW WASHROOMS INCLUDING PLUMBING AND FIXTURES, NEW LIGHTING, REINSTATEMENT OF OPENING IN 2M FLOOR WITH ASSOCIATED STRUCTURAL WORK, 2HR FRR BETWEEN 2 AND 2M FLOORS MAINTAINED WITH 2HR FRR GWB PARTITIONS AND FIRE SHUTTERS. CHANGE OF USE AT GROUND FLOOR FROM RETAIL (GROUP E) TO OFFICES (GROUP D). Base building work done under #18 256994 BA
Every revision the municipality has published for this permit, read directly off the source record rather than the single collapsed status most permit trackers show.
Permit details
The municipal record for this permit.
- Issue date
- Nov 03, 2020
- Project value
- $4.7M
- Project type
- New Build
- Building type
- Commercial
- Commercial category
- Office
- Description
- PROPOSAL FOR INTERIOR RENOVATIONS (TENANT FIT-OUT) TO FLOORS 1 (GROUND), 2 AND 2M (MEZZANINE). SCOPE OF WORK INCLUDES CONSTRUCTION OF NEW PARTITIONS AND FINISHES, INSTALLATION OF MECHANICAL AND ELECTRICAL DISTRIBUTION, INSTALLATION OF NEW WASHROOMS INCLUDING PLUMBING AND FIXTURES, NEW LIGHTING, REINSTATEMENT OF OPENING IN 2M FLOOR WITH ASSOCIATED STRUCTURAL WORK, 2HR FRR BETWEEN 2 AND 2M FLOORS MAINTAINED WITH 2HR FRR GWB PARTITIONS AND FIRE SHUTTERS. CHANGE OF USE AT GROUND FLOOR FROM RETAIL (GROUP E) TO OFFICES (GROUP D). Base building work done under #18 256994 BA
- Builder name
- —
- Permit status
- Completed City's exact wording: Closed
- Work type
- Building Additions/Alterations
- Completed
- 2023-08-22
References & corrections IDs · source · attribution
Contains information licensed under the Open Government Licence, City of Toronto.
CanPermits is not perfect.