CanPermits

New Build permit

63 W 6TH AVENUE

Vancouver , British Columbia

Issued
Issued Jul 04, 2019
Project type
New Build
Value
$17.2M
Status
Issued

Activity at this address

14 permits since 2019

Most recent activity: Jul 2024

Renovation

This permit is one of 14 permits filed at this address.

6 4 2 0 2019 2021 2022 2023 2024
See everything happening at this address · 14 permits

Permit details

The municipal record for this permit.

Trades

Electrical Windows & Doors Foundation / Structural General HVAC Insulation Plumbing Roofing
Issue date
Jul 04, 2019
Project value
$17.2M
Project type
New Build
Building type
Commercial
Description
Certified Professional Program - New Building - To construct a 4-level (6 storey VBBL) mixed-use building consists of Restaurant – Class 1 on level 1 (2nd storey), Manufacturing on level 1 and mezzanine (2nd and 3rd storeys), and General Office on levels 2 to 4 (4th-6th storeys), all over 2 levels (1-storey at grade and 1-storey below grade) of parking, providing 68 parking spaces having vehicular access from the lane. Scope of work also includes relocation, retention, restoration and conservation of the existing dwelling at 35 West 6th Avenue. Separate tenant improvement permits are required for the shell tenant spaces. STAGED CONSTRUCTION Stage 1 - Excavation & Shoring - issued July 4, 2019 Revision 1 - Update work description and terms - issued July 4, 2019 Stage 2 - Full Construction - issued October 2, 2019 Revision 2 - Removed corridors and combined industrial units into one at level 1 (2nd floor) and mezzanine level (3rd floor). Related to DPMA DP-2020-00256. - issued September 30, 2020 Revision 3 - A change of name in Structural firm. Change of floor layout at levels 3 to 5 (4th-6th storeys) to create more suites, additional operable windows at north elevation on levels 1 to 3 (related to DP-2021-00229), revised End of Trip facility layout on level P1, and addition of gender neutral washrooms and universal washrooms on levels 3 to 5. - issued May 7, 2021 Revision 4 - Change of Electrical Engineer of Record from H. Sweeney to K. Zirul. Change one demising wall on level 4, between Unit 411 and 413 to optional (dash lines as shown on approved drawings). Separate permit will be required when new demising walls are to be added. - issued July 28, 2021
Permit status
Issued
Applicant
Susana Chui DBA: Camphora Engineering
References & corrections IDs · source · attribution
Permit ID BP-2018-03892
Full address 63 W 6th Ave, Vancouver, BC, Vancouver, V5Y
Page URL

Contains information licensed under the Open Government Licence, City of Vancouver.

Nearby active addresses

Other addresses with recent permit activity near this permit.

More from Ventana Construction Corporation

View contractor profile

33 other permits on record.