Addition permit
180 MALVERN ST
Toronto , Ontario
- Issued
- Issued May 16, 2019
- Project type
- Addition
- Status
- Completed
Activity at this address
4 permits since 2010
Most recent activity: May 2019
This permit is one of 4 permits filed at this address.
Revision history
3 revisions on file · 2018–2020
-
Closed Rev 02 Issued Jan 28, 2020
Rev 2: REMOVE EXISTING KITCHEN AND LAUNDRY AND PROVIDE IT AT NEW LOCATION ON THE EXISTING GROUND FLOOR PLANProposed basement alterations, interior alterations, rear 2 storey addition, side 2nd floor a… Read full revision note Show less
Rev 2: REMOVE EXISTING KITCHEN AND LAUNDRY AND PROVIDE IT AT NEW LOCATION ON THE EXISTING GROUND FLOOR PLANProposed basement alterations, interior alterations, rear 2 storey addition, side 2nd floor addition, basement walkout, rear deck and rear balcony.
-
Closed Rev 01 Issued May 16, 2019
Revision 01: Roof Structure changed from 2x6 SPF wood rafters to 9.5" TJI rafters. One LVL beam has been provided at second floor MBR to account for the change of existing ceiling joists.Proposed base… Read full revision note Show less
Revision 01: Roof Structure changed from 2x6 SPF wood rafters to 9.5" TJI rafters. One LVL beam has been provided at second floor MBR to account for the change of existing ceiling joists.Proposed basement alterations, interior alterations, rear 2 storey addition, side 2nd floor addition, basement walkout, rear deck and rear balcony.
-
Closed Rev 00 Issued Aug 14, 2018
Proposed basement alterations, interior alterations, rear 2 storey addition, side 2nd floor addition, basement walkout, rear deck and rear balcony.
Every revision the municipality has published for this permit, read directly off the source record rather than the single collapsed status most permit trackers show.
Permit details
The municipal record for this permit.
- Issue date
- May 16, 2019
- Project value
- —
- Project type
- Addition
- Building type
- Single Family
- Description
- Revision 01: Roof Structure changed from 2x6 SPF wood rafters to 9.5" TJI rafters. One LVL beam has been provided at second floor MBR to account for the change of existing ceiling joists.Proposed basement alterations, interior alterations, rear 2 storey addition, side 2nd floor addition, basement walkout, rear deck and rear balcony.
- Builder name
- —
- Permit status
- Completed City's exact wording: Closed
- Work type
- Small Residential Projects
- Completed
- 2020-08-25
References & corrections IDs · source · attribution
Contains information licensed under the Open Government Licence, City of Toronto.
CanPermits is not perfect.