Renovation permit
1476 E 11TH AVENUE
Vancouver , British Columbia
- Issued
- Issued Apr 24, 2018
- Project type
- Renovation
- Value
- $162K
- Status
- Issued
Activity at this address
1 permit since 2018
Most recent activity: Apr 2018
Renovation
This permit is one of 1 permit filed at this address.
Permit details
The municipal record for this permit.
- Issue date
- Apr 24, 2018
- Project value
- $162K
- Project type
- Renovation
- Building type
- Multi Family
- Description
- High Density Housing / Commercial - Addition / Alteration - Exterior and interior alterations to all floors and to change the use of this existing Heritage B building from three housekeeping and three sleeping units and a common storage occupying the entire basement to a multiple conversion dwelling building containing three RENTAL dwelling units with one parking space at the rear. Work to include the removal of the stair and landing on the west side yard and the storage shed at the rear. Building will be fully sprinklered to NFPA 13 standard, and provided with a fire alarm. Note: This existing Part 3 building has been re-classified as Part 9 based on the Code Report prepared by Bill May reviewed and accepted by Boris Turishev. Related to: - AL402141 (Multi-Level Dwelling Unit Egress) - AL402139 (Exposure to Exit Conditions) - AL402142 ( Existing Spatial Separation Conditions) The building is sprinklered to NFPA13 (vs.NFPA13R). NFPA 13 was proposed as a mitigation feature to address Exposure to Exit conditions (AL402139), non-conforming spatial separation conditions( AL402142) and the muilti-level dwelling unit egress (AL402141). All rooms, incl. batrooms and storages are to be sprinklered to NFPA 13. Exit protection is provided by employing closed space fire sprinkles and tempered and laminated safety glass provided with limit stops (<100mm) if operable. This is a rental building, and it has been upgraded to meet S2, F2 and A3 design upgrade levels as per VBBL 2007. In the future this existing building may be converted into strata property if the entire building is upgraded to design upgrade levels F4, S4, N4, A4 and E4, and it is subject to a separate Building Permit application. An occupancy permit and/or a final inspection for the dwelling will not be issued until such time as the Option/SRW agreement has been registered. Original application submitted under BU459928. This project was processed under VBBL 2007. Revision #1 - 20-Dec-2018
- Contractor
- Hicks Interiors Inc
- Permit status
- Issued
- Applicant
- STEFAN BRUNHOFF
References & corrections IDs · source · attribution
Permit ID
BP-2017-02392
Full address
1476 E 11th Ave, Vancouver, BC, Vancouver, V5N
Page URL
Contains information licensed under the Open Government Licence, City of Vancouver.
CanPermits is not perfect.
Please correct us.
Nearby active addresses
Other addresses with recent permit activity near this permit.
More from Hicks Interiors Inc
3 other permits on record.