Renovation permit

6183 CARNARVON STREET

Vancouver , British Columbia

Issued
Issued Dec 08, 2020
Project type
Renovation
Value
$30K
Status
Issued

Activity at this address

1 permit since 2020

Most recent activity: Dec 2020

Renovation

This permit is one of 1 permit filed at this address.

3 2 1 0 2020
See everything happening at this address

Permit details

The municipal record for this permit.

Issue date
Dec 08, 2020
Project value
$30K
Project type
Renovation
Building type
Single Family
Description
Field Review - Addition / Alteration - Interior and exterior alterations, and change of use from One Family Dwelling to One Family Dwelling with a Secondary Suite. Exterior renovations are limited to add a new window on north elevation, alter grades at south, west and north elevations and adding a 4 foot high fence around existing hot tub. REUP form prepared by: Peter Cho (City Green Solutions) 778-316-9053 Energuide file #: 7929D00605 OK for field review as per Eun Jeon, May 21, 2020 Note: - No sprinkler head alterations proposed. District Building Inspector to determine if Sprinkler Permit is required. SP Required per DBI Nov 24/20 - Minor grade changes and new exterior steps to meet living accommodation below finished grade cleared by Sonia Erichsen. - Existing 12' x 22' hot tub to be fenced/enclosed (minimum 4') and all gates and doors are to be equipped with locks and self-closing devices as per Barrie Smith, May 21, 2020. - No strata-titling permitted. - An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. - Dedicated 3'-0" wide firefighting access path with overhead clearance of 2m to be maintained at all times. - Smoke alarms to be installed in conformance with Vancouver Building Bylaw subsections 3.2.4 and 9.10.19. - CO Alarms to be installed in conformance with Vancouver Building Bylaw subsections 6.2.4 and 9.32.4. - All unsafe guards and handrails to be upgraded to the satisfaction of the Chief Building Official. Increase in project value at discretion of District Building Inspector may require additional upgrading as per Table 11.4.3.1 of the VBBL.
Permit status
Issued
Applicant
Chris Ng DBA: Coto Design Inc.
References & corrections IDs · source · attribution
Permit ID DB-2020-01593
Full address 6183 Carnarvon St, Vancouver, BC, Vancouver
Page URL