Renovation permit

4756 ARGYLE STREET

Vancouver , British Columbia

Issued
Issued Oct 06, 2020
Project type
Renovation
Value
$70K
Status
Issued

Activity at this address

4 permits since 2020

Most recent activity: Mar 2024

Demolition

This permit is one of 4 permits filed at this address.

3 2 1 0 2020 2023 2024
See everything happening at this address · 4 permits

Permit details

The municipal record for this permit.

Issue date
Oct 06, 2020
Project value
$70K
Project type
Renovation
Building type
Single Family
Description
Field Review - Addition / Alteration - CF-2020-007723 - Exterior and interior alterations and a change of use from a one family dwelling to a one family dwelling with a secondary suite providing 2 parking spaces with access from the lane. Exterior work to add a new porch cover at the west elevation and to remove the enclosure under the sundeck on the east elevation and to replace new deck guardrail. Scope of work; -To renovate kitchen and millwork on basement and main floor - To renovate bathroom and create a closet to the master bedroom on the upper floor. - Plumbing fixtures and electrical work OK for Field Review per W.Wong, September 3, 2020 REUP submitted per Peter Cho, 778-316-9053 Scope of work to include energy upgrade in accordance with Article 11.2.1.4 of the 2019 Vancouver Building By-law. Blower door air sealing as per the Energy Efficiency Upgrade Details noted in the Energuide Report. #1-4756 Arygle St - One Family Dwelling (1st & storey storey, west portion of basement) #2-4756 Argyle St - Secondary Suite (east portion of basement) Note: 1) No strata-titling will be permitted. 2) An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. 3) Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and within 5m outside each sleeping areas on each storey as per Building Bylaw 9.10.19. 4) Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2. & Bulletin 2007-007-BU/EL 5) Upgrade work under Part 11 (based on value of work – energuide related Part 11.2.1.4.) 6) Ceiling height to be a min. 6ft 6" over 80% of the suite area and all exit routes
Contractor
tina dhillon DBA: Tina Dhillon

Individual names are not promoted as contractor profiles.

Permit status
Issued
References & corrections IDs · source · attribution
Permit ID DB-2020-02743
Full address 4756 Argyle St, Vancouver, BC, Vancouver
Page URL

Contains information licensed under the Open Government Licence, City of Vancouver.