Renovation permit
2517 WILLIAM STREET
Vancouver , British Columbia
- Issued
- Issued Apr 16, 2021
- Project type
- Renovation
- Value
- $60K
- Status
- Issued
Activity at this address
2 permits since 2019
Most recent activity: Apr 2021
Renovation
This permit is one of 2 permits filed at this address.
Permit details
The municipal record for this permit.
Trades
HVAC
Plumbing
Windows & Doors
Foundation / Structural
- Issue date
- Apr 16, 2021
- Project value
- $60K
- Project type
- Renovation
- Building type
- Single Family
- Description
- Field Review - Addition / Alteration - Interior and exterior alterations to the main and basemen floors, and change of use of this existing one storey with a basement, one family dwelling to one family dwelling with a secondary suite, with one off street parking space provided in the detached garage, have vehicular access off the rear lane. Scope of work: - removing unauthorized rear deck and replacing door to the deck with a window. - demo & install interior doors, walls, boiler, plumbing fixtures and EL work on basement & main fl - re&re two doors on North & one window on West EL. Note: 1. Previous building permit of BP-2019-03387 will be cancelled upon the issuance of this permit. 2. District Building Inspector to determine at field review inspection if Structural submission is required for the posts under the existing drop beam in the basement. 3. Two off street parking spaces proposed under DP-2020-00089, but under this permit off street parking space reduced to one. REUP submitted per #1 - 2517 William St - One Dwelling (northeast portion of the basement and 1st storey) #2 - 2517 William St - Secondary Suite (south portion and northwest portion of the basement) 1) No strata-titling will be permitted. 2) An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. 3) Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and within 5m outside each sleeping areas on each storey as per Building Bylaw 9.10.19. 4) Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2. & Bulletin 2007-007-BU/EL 5) Upgrade work under Part 11 (based on value of work – energuide related Part 11.2.1.4.) 6) Ceiling height to be a min. 6ft 6" over 80% of the suite area and all exit routes
- Contractor
- Khang Nguyen DBA: Architrix Design Studio
- Permit status
- Issued
References & corrections IDs · source · attribution
Permit ID
DB-2020-02886
Full address
2517 William St, Vancouver, BC, Vancouver
Page URL
Contains information licensed under the Open Government Licence, City of Vancouver.
CanPermits is not perfect.
Please correct us.
Nearby active addresses
Other addresses with recent permit activity near this permit.
More from Khang Nguyen DBA: Architrix Design Studio
83 other permits on record.