CanPermits

Renovation permit

2517 WILLIAM STREET

Vancouver , British Columbia

Issued
Issued Apr 16, 2021
Project type
Renovation
Value
$60K
Status
Issued

Activity at this address

2 permits since 2019

Most recent activity: Apr 2021

Renovation

This permit is one of 2 permits filed at this address.

3 2 1 0 2019 2021
See everything happening at this address · 2 permits

Permit details

The municipal record for this permit.

Trades

HVAC Plumbing Windows & Doors Foundation / Structural
Issue date
Apr 16, 2021
Project value
$60K
Project type
Renovation
Building type
Single Family
Description
Field Review - Addition / Alteration - Interior and exterior alterations to the main and basemen floors, and change of use of this existing one storey with a basement, one family dwelling to one family dwelling with a secondary suite, with one off street parking space provided in the detached garage, have vehicular access off the rear lane. Scope of work: - removing unauthorized rear deck and replacing door to the deck with a window. - demo & install interior doors, walls, boiler, plumbing fixtures and EL work on basement & main fl - re&re two doors on North & one window on West EL. Note: 1. Previous building permit of BP-2019-03387 will be cancelled upon the issuance of this permit. 2. District Building Inspector to determine at field review inspection if Structural submission is required for the posts under the existing drop beam in the basement. 3. Two off street parking spaces proposed under DP-2020-00089, but under this permit off street parking space reduced to one. REUP submitted per #1 - 2517 William St - One Dwelling (northeast portion of the basement and 1st storey) #2 - 2517 William St - Secondary Suite (south portion and northwest portion of the basement) 1) No strata-titling will be permitted. 2) An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. 3) Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and within 5m outside each sleeping areas on each storey as per Building Bylaw 9.10.19. 4) Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2. & Bulletin 2007-007-BU/EL 5) Upgrade work under Part 11 (based on value of work – energuide related Part 11.2.1.4.) 6) Ceiling height to be a min. 6ft 6" over 80% of the suite area and all exit routes
Permit status
Issued
References & corrections IDs · source · attribution
Permit ID DB-2020-02886
Full address 2517 William St, Vancouver, BC, Vancouver
Page URL

Contains information licensed under the Open Government Licence, City of Vancouver.

Nearby active addresses

Other addresses with recent permit activity near this permit.

More from Khang Nguyen DBA: Architrix Design Studio

View contractor profile

83 other permits on record.