Renovation permit

1223 E PENDER STREET

Vancouver , British Columbia

Issued
Issued Jun 04, 2021
Project type
Renovation
Value
$360K
Status
Issued

Activity at this address

4 permits since 2017

Most recent activity: Jun 2021

Demolition

This permit is one of 4 permits filed at this address.

3 2 1 0 2017 2018 2021
See everything happening at this address · 4 permits

Permit details

The municipal record for this permit.

Trades

General Foundation / Structural HVAC Plumbing Windows & Doors
Issue date
Jun 04, 2021
Project value
$360K
Project type
Renovation
Building type
Commercial category
Warehouse
Description
Field Review - Addition / Alteration - Interior alterations for the installation of a "Sky Locker" System (storage Lockers) on the 1st, 2nd & 3rd levels in this existing 4 storey, Self-Storage Warehouse (F2) Building on this site. Scope of work includes: columns, bracing, security mesh, partitions, swing doors and deck for the construction of a total of 281 additional storage "Sky" lockers (height of 3'.10" or 4' / area between 16 sq. ft. and 60 sq. ft. / max load of 62.5 lbs. per 1 sq. ft.) above the existing storage lockers. Stair ladder to provide access to upper sky lockers. REVISION #1: change the swing doors to roll-up doors on all the proposed sky-lockers. Aug. 31, 2021 mlh Letter of Operation provided by applicant Hugh Cartwright, DBA NationWide Self Storage. Letter of verification of the use and design dated May 25, 2021 provided by Murray Johnson, P. Eng. Tenant: Nationwide Self Storage OK for Field Review per A. Cashato & A. Campbell, Nov 17, 2020. DP not required - No increase in FSR per J. Greer, Nov 17, 2020. Notes: ~ Energy Upgrade: Exempt as per Project type. ~ Schedule B Architectural and Structural submitted by David Seberras, P. Eng. of Seberras Professional Services Ltd., Tel: 905 536-7144. ~ Sprinkler Comfort letter dated Jan 19, 2021, submitted by Steven Lee, P. Eng. of Northwest Sprinkler Company Ltd. ~ District Building Inspector (DBI) to confirm sprinkler coverage at the new skylockers. Sprinkler coverage shall meet the requirements of VBBL and NFPA 13. ~ Maintain minimum 18" clearance between top of storage and sprinkler deflector. ~ Maintain minimum clearance of 18" between top of partition and sprinkler deflector. ~ Provide wire mesh top on skylockers (see base building sprinkler permit SP-2018-02701 and January 19, 2021 letter from Steven Lee, P.Eng. of NWSC). ~ Separate sprinkler permit and documents required for alterations to the fire suppression system.
Permit status
Issued
References & corrections IDs · source · attribution
Permit ID BP-2020-03632
Full address 1223 E Pender St, Vancouver, BC, Vancouver
Page URL

Contains information licensed under the Open Government Licence, City of Vancouver.