Renovation permit

1075 DOUGLAS CRESCENT

Vancouver , British Columbia

Issued
Issued Sep 27, 2021
Project type
Renovation
Value
$600K
Status
Issued

Activity at this address

2 permits since 2021

Most recent activity: Sep 2024

Renovation

This permit is one of 2 permits filed at this address.

3 2 1 0 2021 2024
See everything happening at this address · 2 permits

Permit details

The municipal record for this permit.

Issue date
Sep 27, 2021
Project value
$600K
Project type
Renovation
Building type
Single Family
Description
Field Review - Addition / Alteration - Exterior and Interior alterations and change of use from community care home to one family dwelling at this existing 3 storey plus basement building on this site. Exterior alterations: 1. Removal of the unauthorized plastic cover at the rear on the 3rd storey. 2. Removal of unauthorized aluminum cover at the rear on the 1st storey. 3. Removal of door, landing and stairs on 1st storey on the east elevation. 4. Demo walls and door at the south elevation adjacent to the sleeping porch at the 1st storey and install 2 sets of sliding doors. 5. Installation of heat pump at the rear east elevation of the building. 6. Removal of exterior or chimney from the roof. 7. To validate the exterior egress stairs at the rear. 8. Replacement of exterior windows are to match existing windows. Interior Alterations: Basement - Removal of interior doors & walls, plumbing fixtures, chimney, furnace, washer, dryer. Area converted into Rec Room with no bar sink - New doors & interior walls, relocate HWT and electrical panel, update bathroom 1st fl - Removal of interior doors & walls, plumbing fixtures, kitchen appliances - Install doors & interior walls, fireplace, closet, millwork, relocate bathroom & update kitchen 2nd fl - Removal of doors, interior walls, and closets - Update & enlarge bathroom, one new bathroom, new doors & interior walls 3rd fl - Removal & install of interior walls & doors, re & re plumbing fixtures - Removal of chimney from basement to 3rd storey - Sprinklering the entire building to NFPA 13 D standards. - Install interconnected, hardwired, 120 volt smoke alarms as per VBBL 9.10.19 and Carbon Monoxide Alarm as per VBBL 9.3.32.4.2 REUP submitted per Scott Silverthorn, 604-787-1952 Schedule B Structural submitted per Carlos Chiu, 604-737-9830 A/C unit to conform to City of Vancouver Noise By-Law #6555
Contractor
DOS Design Group
Permit status
Issued
References & corrections IDs · source · attribution
Permit ID DB-2021-03601
Full address 1075 Douglas Cres, Vancouver, BC, Vancouver
Page URL

Contains information licensed under the Open Government Licence, City of Vancouver.

Nearby active addresses

Other addresses with recent permit activity near this permit.

More from DOS Design Group

View contractor profile

25 other permits on record.