Renovation permit
3277 W BROADWAY
Vancouver , British Columbia
- Issued
- Issued Sep 08, 2021
- Project type
- Renovation
- Value
- $125K
- Status
- Issued
Activity at this address
1 permit since 2021
Most recent activity: Sep 2021
Renovation
This permit is one of 1 permit filed at this address.
Permit details
The municipal record for this permit.
- Issue date
- Sep 08, 2021
- Project value
- $125K
- Project type
- Renovation
- Building type
- —
- Commercial category
- Retail
- Description
- Field Review - Addition / Alteration - Interior alterations and change of use of the existing Retail limited-food (E) to a new Retail-Cannabis (E) store to provide improvements for a new tenant at 3277 W Broadway (approx. 809 sq. ft.) on the 1st floor in this existing one storey commercial building. Scope of work includes: alterations to remove partitions, doors, ceilings, washroom, plumbing fixtures and heat pump; one door removed from rear common corridor; new partitions, universal washroom, plumbing fixtures, new doors, millwork, ceiling/tiles, vault, new power, lighting, paint and finishes throughout. Tenant: 1223941 BC Ltd. (dba Chronic Hub Cannabis Company) OK For Field Review per Kim V - Apr 20/21 Rev #1 (R. Foster) issued Jan 14, 2022 to remove contractor, Five River Construction Ltd. from the permit as per email request dated Dec 22, 2021 received from Harp Lalli, President, Five River Construction Ltd. Rev #2 1) Change of business name to 1223941 BC ltd (dba Chronic Hub Cannabis Company) on the architectural drawings. 2) Change of Hours of Operation on Cover sheet 3) Deletion of entry vestibule from the floor plan, section and schedules. B. Wong - Jan 26/22 Notes: ~ Energy Upgrade: E2 - Lighting - Upgrade to incorporate Automatic Full Shut off (per 9.4.1.1.(h) of ASHRAE 90.1-2016. ~ District Building Inspector to determine if a Seismic Restraint letter is required for shelving height over 6ft. ~ Related to time limited/exclusive use Development Permit, DP-2019-00322 and MA DP-2021-00601. ~ Building Not Sprinklered – No sprinkler permit required. ~ Approval subject to Sequence of Operation and Commitment to decommission letter dated June 24, 2021 for the use of electromagnetic locks.
- Contractor
- Space in Time Project Management Ltd
- Permit status
- Issued
- Applicant
- Maria Kim-Petzel DBA: Raw Interior design Inc.
References & corrections IDs · source · attribution
Permit ID
BP-2021-01696
Full address
3277 W Broadway, Vancouver, BC, Vancouver
Page URL
Contains information licensed under the Open Government Licence, City of Vancouver.
CanPermits is not perfect.
Please correct us.
Nearby active addresses
Other addresses with recent permit activity near this permit.
More from Space in Time Project Management Ltd
30 other permits on record.