Renovation permit
1068 W 46TH AVENUE
Vancouver , British Columbia
- Issued
- Issued Apr 19, 2023
- Project type
- Renovation
- Value
- $210K
- Status
- Issued
Activity at this address
1 permit since 2023
Most recent activity: Apr 2023
Renovation
This permit is one of 1 permit filed at this address.
Permit details
The municipal record for this permit.
- Issue date
- Apr 19, 2023
- Project value
- $210K
- Project type
- Renovation
- Building type
- Single Family
- Description
- Field Review - Addition / Alteration - Exterior and interior alterations to provide improvements and to change use from Single Detached House to Single Detached House with a Secondary Suite building on this existing site, adding six new plumbing fixtures. Scope of work includes a new heat pump, extending the exterior south-east basement walls to match the walls above, new windows on the east and west elevations, new footing in the basement, removing a structural column in the family room, changing the single overhead garage door to two overhead doors and the removal of the unapproved rear deck covers. REVISION #1: To assign new addresses. - B. Wong - May 9/23 Ok for field review as per Kirat Kang January 18, 2023 Notes: - Schedule B, Structural, Ke Jian Ma, P.Eng, - REUP submitted by Tao Xue, 778-898-3296. Scope of work to include energy upgrade in accordance with Article 11.2.1.4 of the 2019 Vancouver Building By-law and as per the Energy Efficiency Upgrade Details noted in the Energuide Report. *Selected upgrades: New R40 attic insulation and new heat pump. - This building is not sprinklered. - No strata-titling will be permitted. - An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. - Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and on each storey as per Building Bylaw 9.10.19. - Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2. - Upgrade work under Part 11 (based on value of work – energuide related Part 11.2.1.4.) - Ceiling height to be a min. 6ft 6" over 80% of the suite area and all exit routes - Dedicated 3'-0" wide firefighting access path with overhead clearance of 2m to be maintained at all times
- Permit status
- Issued
- Applicant
- Feeny Chen DBA: TFMD Consulting Inc.
References & corrections IDs · source · attribution
Permit ID
DB-2023-00284
Full address
1068 W 46th Ave, Vancouver, BC, Vancouver
Page URL
Contains information licensed under the Open Government Licence, City of Vancouver.
CanPermits is not perfect.
Please correct us.
Nearby active addresses