Renovation permit
1177 W HASTINGS STREET
Vancouver , British Columbia
- Issued
- Issued Aug 10, 2022
- Project type
- Renovation
- Value
- $35K
- Status
- Issued
Activity at this address
77 permits since 2017
Most recent activity: Jul 2026
Renovation
This permit is one of 77 permits filed at this address.
Permit details
The municipal record for this permit.
- Issue date
- Aug 10, 2022
- Project value
- $35K
- Project type
- Renovation
- Building type
- Commercial
- Commercial category
- Office
- Description
- Field Review - Addition / Alteration - #1818 - 18th Floor (* changed from #1816 -See Revision #2) Interior alterations to provide tenant improvements and to expand the existing office tenant in #1816 into #1818 (retaining #1816) in this existing commercial building on this site. Scope of work: Remove a portion of the demising wall and combine #1816 and #1818, demolish/construct partition walls, glazing partition, remove existing flooring, doors, new carpet, repaint walls, new lighting fixtures, electrical and sprinkler work to suit. REVISION #1: interior layout changes and increase in project value from $20,000.00 to $35,000.00. Aug 30, 2022 mlh *REVISION #2: close off #1818 main entrance by infilling the existing opening, delete the addition of the 5'-1" x 7'-0" glazing wall with the 2" vinyl strip and to change #1816 to #1818 for the combined units. Oct 3, 2022 mlh OK for Field Review per A. Wroblewski; May 30, 2022 Building Sprinklered – Separate sprinkler permit required for proposed sprinkler work. E2 - Lighting - Upgrade to incorporate Automatic Partial OFF (per 9.4.1.1.(g) of ASHRAE 90.1-2016)\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t Energy checklist is currently no longer required with your Building Permit (BP) application. Some supporting documents are still required at BP stage, specifically Envelope and HVAC, if applicable. Service Water Heating and Lighting supporting documents, if applicable, must be submitted with your related trades permits (e.g. electrical and plumbing). All energy upgrades will be checked during inspections stage. It is the applicant’s responsibility to identify and note all required upgrades including energy upgrades on their BP drawings at BP stage.
- Contractor
- Focus Project Management Ltd
- Permit status
- Issued
- Applicant
- Erickson Yan DBA: Focus Project Management Ltd.
References & corrections IDs · source · attribution
Permit ID
BP-2022-02799
Full address
1177 W Hastings St, Vancouver, BC, Vancouver
Page URL
Contains information licensed under the Open Government Licence, City of Vancouver.
CanPermits is not perfect.
Please correct us.
Nearby active addresses
Other addresses with recent permit activity near this permit.
More from Focus Project Management Ltd
78 other permits on record.