Renovation permit
970 ROBSON STREET
Vancouver , British Columbia
- Issued
- Issued Feb 11, 2022
- Project type
- Renovation
- Value
- $600K
- Status
- Issued
Activity at this address
3 permits since 2020
Most recent activity: Jul 2023
Renovation
This permit is one of 3 permits filed at this address.
Permit details
The municipal record for this permit.
Trades
Electrical
HVAC
Plumbing
Windows & Doors
Foundation / Structural
General
Insulation
- Issue date
- Feb 11, 2022
- Project value
- $600K
- Project type
- Renovation
- Building type
- Commercial
- Commercial category
- Retail
- Description
- Field Review - Addition / Alteration - Interior and exterior alterations to provide tenant improvements for this existing retail tenant in this existing commercial building. Scope of Work: Installing racking, reconfiguring the entire interior, partial removal of exterior canopies and alterations to the exterior glazing and cladding. OK for Field Review as per J.Bal - Nov 9/21 Ok'd by POD - M Linehan, Nov 9/21 REVISION #1: - Layout, partition and lighting changes to accommodate the new location of the washrooms due to site conditions. - Ceiling added to the exit corridor of the stock room area. - Exit signs and fire alarm devices relocated to accommodate layout changes. - New guardrail connection changed to match existing guardrails. B. Wong - August 12/22 Notes: - This building is sprinklered. A separate sprinkler permit is required for all related work. - Energy Upgrade: E2 - Retrofit Path: 1 @ E2 - Schedule A & Schedule B (Architectural), Richard Witt, Architect, 416-589-1240 - Schedule B (Structural), Ramin Papaei, P.Eng, 604-738-0048 - Schedule B (Structural - storage racking), B Hanson, P.Eng, 509-921-7731 - Schedule B (Mechanical/Plumbing), Qing Ping Zhang, P.Eng, 905-946-4260 - Schedule B (Electrical), Zhao Hui Guo, P.Eng, 905-946-4260 - Schedule D, Richard Witt, Architect, 416-589-1240 Energy checklist is currently no longer required with your Building Permit (BP) application. Some supporting documents are still required at BP stage, specifically Envelope and HVAC, if applicable. Service Water Heating and Lighting supporting documents, if applicable, must be submitted with your related trades permits (e.g. electrical and plumbing). All energy upgrades will be checked during inspections stage. It is the applicant’s responsibility to identify and note all required upgrades including energy upgrades on their BP drawings at BP stage.
- Permit status
- Issued
References & corrections IDs · source · attribution
Permit ID
DB-2021-05798
Full address
970 Robson St, Vancouver, BC, Vancouver
Page URL
Contains information licensed under the Open Government Licence, City of Vancouver.