Renovation permit
8591 RIVER DISTRICT CROSSING
Vancouver , British Columbia
- Issued
- Issued Aug 23, 2022
- Project type
- Renovation
- Value
- $500K
- Status
- Issued
Activity at this address
3 permits since 2021
Most recent activity: Apr 2023
Renovation
This permit is one of 3 permits filed at this address.
Permit details
The municipal record for this permit.
Trades
Electrical
HVAC
Windows & Doors
- Issue date
- Aug 23, 2022
- Project value
- $500K
- Project type
- Renovation
- Building type
- Commercial
- Commercial category
- Restaurant
- Description
- High Density Housing / Commercial - Addition / Alteration - Interior alterations: Interior alterations and to change the major occupancy from Retail (group E) into Restaurant Class -1 (group A2) in this existing mixed use building on this site. Related to DP-2021-00971 Building Review Branch Notes: 1) Total proposed Occupant load is 71 seats + 7 staffs = 78 Persons. 2) A permanent sign indicating the above proposed occupant load shall be posted in a conspicuous location near the suite's principal entrance. 3) Separate permit will be required for any changes to the interior seating. 4) Separate permit is required for outdoor patio seating. Additional washroom will be required if total interior and exterior occupant load exceed 100 persons. 5) Sprinkler commitment letters submitted by the Tenant and the Fire Protection Engineer to provide a sprinkler trade permit application within 60 days of the building permit issuance. Mechanical Review Notes: 1. Class 1 cooking operations (Grease-Laden Vapours). 2. Commercial kitchen exhaust systems to NFPA 96 (two Type 1 hoods). Revision No. 1 Feb. 7, 2023 issued. a) Washrooms and mop closet locations revised and all related plans updated as needed. b) Shifted some kitchen equipment in Dish [109]. c) Deleted one (K16) burner and shifted some equipment in Kitchen [105] incl. hand sink. d) Removed built in millwork counter in Bar [104] and shifted location of hand sink. e) Centered walk-in cooler doors thus adjusted shelving depths. f) Electrical drawings revised as per items a to e above. g) Mechanical drawings revised as per items a to e above. h) Mechanical revised HVAC ducting sizing at exterior louvres. Note: "This permit has been reviewed under the 2019 Vancouver Building By-law (#12511)."
- Permit status
- Issued
References & corrections IDs · source · attribution
Permit ID
BP-2022-02785
Full address
8591 River District Crossing, Vancouver, BC, Vancouver
Page URL
Contains information licensed under the Open Government Licence, City of Vancouver.
CanPermits is not perfect.
Please correct us.
Nearby active addresses
Other addresses with recent permit activity near this permit.
More from Maria Kim-Petzel DBA: Raw Interior design Inc
12 other permits on record.