Renovation permit

1611 CEDAR CRESCENT

Vancouver , British Columbia

Issued
Issued Nov 03, 2023
Project type
Renovation
Value
$412K
Status
Issued

Activity at this address

1 permit since 2023

Most recent activity: Nov 2023

Renovation

This permit is one of 1 permit filed at this address.

3 2 1 0 2023
See everything happening at this address

Permit details

The municipal record for this permit.

Issue date
Nov 03, 2023
Project value
$412K
Project type
Renovation
Building type
Single Family
Description
Low Density Housing - Addition / Alteration - Exterior and interior alterations to add to the side and rear of the basement and main floor, add a new deck at the main floor, add a new second floor balcony for this existing two and a half storey, plus basement, one family dwelling with detached one car garage having vehicular access from Cedar Crescent on this inside double fronting site. Work to include a new pool house, drain tiles, chimney removal and renovations to the interior of the existing one-car garage for pool mechanical equipment. REVISION #1: 1) Update the proposed location of the heat pump from the balcony to the exterior north side of the main building. 2) Revise the window size in the kitchen on the west side of the main floor. 3) Remove a window in the powder room on the west side of the main floor. 4) Add a hot tub on the south-west corner of the outdoor pool. 5) Add a planter box beside the south side deck. 6) Remove the pavers by the pool shed. 7) Rear deck design alteration with no change to the dimensions. 8) New EV Charger in the garage. B.Wong - Apr 18/24 Notes: This building is not sprinklered. - Schedule A & B, Structural, Kosta Marcakis, P. Eng, Struct. Eng, 604-254-0868. - Schedule B, Structural (Hot tub only), Boris Klarich, P. Eng, 604-619-8875. - Schedule B, Geothechnical, Iulian Crudu, P.Eng, 604-553-4984. - Schedule D & B, Architectural, Iqbal Jamal, P. Eng, 780-604-6172. -REUP Submitted by Amir Ekhlasi, Enersaver Solutions Inc, 604-841-1717. *Selected upgrades: increase attic insulation to R28, remove one fuel based fireplace, heat pump displacement. - Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and hallways on each storey as per Building Bylaw 9.10.19. - Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2.
Permit status
Issued
Applicant
John Friswell DBA: CCI -Fairmile Group Ltd.
References & corrections IDs · source · attribution
Permit ID BP-2023-01774
Full address 1611 Cedar Cres, Vancouver, BC, Vancouver
Page URL

Contains information licensed under the Open Government Licence, City of Vancouver.

Nearby active addresses

Other addresses with recent permit activity near this permit.

More from Canadian Constructors International Ltd

View contractor profile

2 other permits on record.