CanPermits

Renovation permit

7786 ONTARIO STREET

Vancouver , British Columbia

Issued
Issued Aug 01, 2023
Project type
Renovation
Value
$150K
Status
Issued

Activity at this address

1 permit since 2023

Most recent activity: Aug 2023

Renovation

This permit is one of 1 permit filed at this address.

3 2 1 0 2023
See everything happening at this address

Permit details

The municipal record for this permit.

Trades

General Foundation / Structural Roofing
Issue date
Aug 01, 2023
Project value
$150K
Project type
Renovation
Building type
Description
Low Density Housing - Addition / Alteration - Exterior and Interior alterations to validate an addition (approx. 774 sq. ft. - enclose the carport, add new storage on the 1st floor and expand the 2nd floor deck with a new aluminum roof over) and change the use of the 1st floor to a Secondary suite (ancillary residential unit) in this existing, 2 storey (slab on grade), Single Detached House and secondary suite with 2 surface parking spaces having vehicular access from the lane on this inside with lane site. Related to DP-2019-00191 and Board of Variance appeal No. Z3564 approved November 17, 2020. Schedule B:GEOTECHNICAL — temporary,GEOTECHNICAL — permanent, Jason Hui, P.Eng. 778 319 3403 Notes: -Schedule B Structural, Geotechnical Temporary and Geotechnical Permanent submitted by Shamsul Alam Shikder, P. Eng. of Shikder Design and Drafting Ltd., Tel: 778 889 3740. -Revised REUP submitted by ARSHDEEP SANDHU 9F19, 778-317-4850 - Energy Upgrade as per REUP - REUP has been approved by the DBI - Renovation Part 11 classification a Major Horizontal addition - This permit has been issued under the VBBL 2019, with updated energy requirements as per bylaw # 12997 effective Jan 01, 2022. - No strata-titling will be permitted. - An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. - Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and on each storey as per Building Bylaw 9.10.19. - Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2. - Ceiling height to be a min. 6ft 6" over 80% of the suite area and all exit routes - Dedicated 3'-0" wide firefighting access path with overhead clearance of 2m to be maintained at all times - This building is not sprinklered. DBI to determine on site if a separate sprinkler permit is required.
Permit status
Issued
References & corrections IDs · source · attribution
Permit ID BP-2022-00018
Full address 7786 Ontario St, Vancouver, BC, Vancouver
Page URL

Contains information licensed under the Open Government Licence, City of Vancouver.

Nearby active addresses

Other addresses with recent permit activity near this permit.

More from Shamsul Shikder DBA: shikder design and drafting

View contractor profile

17 other permits on record.