Renovation permit

1735 E 2ND AVENUE

Vancouver , British Columbia

Issued
Issued Aug 31, 2023
Project type
Renovation
Value
$972K
Status
Issued

Activity at this address

3 permits since 2021

Most recent activity: Feb 2025

Renovation

This permit is one of 3 permits filed at this address.

3 2 1 0 2021 2023 2025
See everything happening at this address · 3 permits

Permit details

The municipal record for this permit.

Issue date
Aug 31, 2023
Project value
$972K
Project type
Renovation
Building type
Single Family
Description
Low Density Housing - Addition / Alteration - Exterior and interior alterations to provide improvements, and to change of use of this existing two-storey plus basement Character Single Detached House to a Single Detached House with Secondary Suite, with 1 off-street parking space provided in the attached garage having vehicular access off the flanking lane. Scope of work includes lowering the foundation and providing a new basement slab, add an elevator, addition on the north portion of the house, reconstruction of the garage, interior alterations to the basement, second floor bathroom and bedroom, kitchen, adding new windows on east side and removing existing fireplace/chimney. Building Depth OK to relax per S. Erichsen, Jan 17, 2023 Architectural Schedule B and Schedule A submitted by Vipul Chauhan Architect, AIBC, AAA, OAA, MRAIC, 604.264.1450 Structural Schedule B submitted by Dragan Todorovic, P. Eng., 604.264.1450 Schedule D submitted by Vipul Chauhan Architect, AIBC, AAA, OAA, MRAIC, 604.264.1450 Renovation Energy Upgrade Proposal provided by Doug Martin of Energy Smart Consulting, 604.614.7985 Retention Drawings, Assurance of Retention, Sequence of Construction submitted by Vipul Chauhan Architect, AIBC, AAA, OAA, MRAIC, 604.264.1450 Building to be sprinklered in accordance with NFPA 13D requirements. A separate Sprinkler Permit is required. Note: - Heat pump located on the East side of the building - No strata-titling will be permitted. - An annual Vancouver Business License must be obtained prior to the rental of this approved one-family dwelling and/or secondary suite on this site. - Install interconnected, hardwired, 120 volt smoke alarms with battery back-up and silencing feature, in each sleeping unit and within 5m outside each sleeping areas on each storey as per Building Bylaw 9.10.19. - Install Carbon Monoxide Alarm as per Building By-Law 9.32.4.2. & Bulletin 2007-007-BU/EL
Permit status
Issued
Applicant
Vipul Chauhan DBA: Contoura Architecture Ltd.
References & corrections IDs · source · attribution
Permit ID DB-2023-00267
Full address 1735 E 2nd Ave, Vancouver, BC, Vancouver
Page URL

Contains information licensed under the Open Government Licence, City of Vancouver.

Nearby active addresses

Other addresses with recent permit activity near this permit.

More from C J Smith Contracting Ltd

View contractor profile

5 other permits on record.