CanPermits

New Build permit

4612 ANGUS DRIVE

Vancouver , British Columbia

Issued
Issued Mar 23, 2020
Project type
New Build
Value
$1.4M
Status
Issued

Activity at this address

3 permits since 2020

Most recent activity: Mar 2020

Demolition

This permit is one of 3 permits filed at this address.

3 2 1 0 2020
See everything happening at this address · 3 permits

Permit details

The municipal record for this permit.

Trades

HVAC Electrical Foundation / Structural Insulation Plumbing Roofing Windows & Doors
Issue date
Mar 23, 2020
Project value
$1.4M
Project type
New Build
Building type
Single Family
Description
Low Density Housing - New Building - 2 STOREY 1FD + 4 CAR GARAGE To construct a 2 storey + basement/cellar one-family dwelling ($1,424,545.00) with a detached accessory building (garage) , at the rear providing 4 parking spaces, having vehicular access from the lane. 1. A/C Unit proposed at rear yard. 2.\tNo bar sink proposed. 3.\tSchedule B: (Pawanjit Aulakh) P.Eng (604.543.8044) Structural 4.\tSchedule B: (Paullus K.F. Young) P.Eng (604.841.7748) Geotechnical 5.\tBC Housing (BUILDER COMPANY NAME) 6. Residential Elevator Proposed. B44 standard requirements to be met. This is a 2 storey building pursuant to the Zoning and Development By-Law ******THIS PERMIT HAS BEEN ISSUED UNDER THE REQUIREMENTS OF VBBL 2014 ****** All rooms adjacent to East and West exposing building face shall be sprinklered. "Combustible projections or roof soffits on an exposing building face shall not project to less than .45m from the property line and shall be in compliance with VBBL 2014 9.10.15.5.(9) The entire building, INCLUDING THE ATTACHED GARAGE (if applicable), to be sprinklered to NFPA 13D. Any alterations or conversions to the attached garage (if applicable) to habitable living space shall not be permitted without first obtaining the approval of the Director of Planning and the Chief Building Official. Thermal protection measures and Laneway house design guidelines shall be required to be met prior to the approval of the conversion. The outdoor mechanical equipment (SwimSpa), to comply with VBBL section 9.33.4.7: 1) To maintain equipment in place during structural movement 2) To support and with stand expected loads and forces. Also SwimSpa shall conform to the Noise Control bylaw #6555 (when the equipment is not within the building).
Permit status
Issued
References & corrections IDs · source · attribution
Permit ID DB-2019-05212
Full address 4612 Angus Dr, Vancouver, BC, Vancouver
Page URL

Contains information licensed under the Open Government Licence, City of Vancouver.

Nearby active addresses

Other addresses with recent permit activity near this permit.

More from Crown Pacific Development Ltd

View contractor profile

32 other permits on record.