Renovation permit

1095 W PENDER STREET

Vancouver , British Columbia

Issued
Issued Nov 19, 2024
Project type
Renovation
Value
$460K
Status
Issued

Activity at this address

56 permits since 2017

Most recent activity: Feb 2026

Renovation

This permit is one of 56 permits filed at this address.

9 6 3 0 2019 2020 2021 2022 2023 2024 2025 2026
See everything happening at this address · 56 permits

Permit details

The municipal record for this permit.

Issue date
Nov 19, 2024
Project value
$460K
Project type
Renovation
Building type
Commercial
Commercial category
Office
Description
Field Review - Addition / Alteration - Unit #900 - 9th and 10th floors (#1020, #1050, #1070) Interior alterations to provide tenant improvements for this existing office tenant on the 9th floor and on the 10th floor of this existing commercial building. Scope of work: Full demo on the 9th floor and construct new partition walls, doors for new layout, remove all the demising wall and combine all the office units into one on the 10th floor, electrical and sprinkler work. REVISION #1: To configure the office rooms walls and doors on the east-south elevation on the 9th floor and throughout the 10th floor, and add card readers on both floors. (See detailed scope on the application form) - Feb 7/25 - LLL REVISION #2: To install a maglock with sequence of operation and minor office layout configuration adjustments. Increase in project cost of $10,000. - May 15/25 - LLL REVISION #3 - To make interior changes including wall layout, doors, lighting, and sprinklers on level 9 and 10. - Jan 14/26 - LLL NOTE: Concord Pacific will occupy both floors entirely thru interconnecting stairs. TENANT: Concord Pacific Development Corp Letters of Assurance submitted: \t\t Schedule A and Architectural Schedule B by Julien Leger, Architect, AIBC., 604.688.3252\t\t Electrical Schedule B by Steven Nemetz, P.Eng., 604.736.6562\t\t Plumbing/Mechanical Schedule B by Alexis Lam, P. Eng., 604.684.3412\t\t Building Sprinklered – Separate sprinkler permit required for proposed sprinkler work. Energy checklist is currently no longer required with your Building Permit (BP) application. Some supporting documents are still required at BP stage, specifically Envelope and HVAC, if applicable. Service Water Heating and Lighting supporting documents, if applicable, must be submitted with your related trades permits (e.g. electrical and plumbing).
Permit status
Issued
References & corrections IDs · source · attribution
Permit ID BP-2024-03306
Full address 1095 W Pender St, Vancouver, BC, Vancouver
Page URL

Contains information licensed under the Open Government Licence, City of Vancouver.

Nearby active addresses

Other addresses with recent permit activity near this permit.

More from Julien Leger DBA: Francl Architecture Inc

View contractor profile

26 other permits on record.